Maybe, and the answer depends less on your headcount than on which other OSHA rules reach your workplace. Under 29 CFR 1910.38, an Emergency Action Plan is required whenever another standard in Part 1910 requires one. The rule itself does not say "every employer needs one." It points to other standards, and those standards do the triggering.

That is why two similar employers can get different answers. A shop that wants everyone to leave on the alarm, with no extinguishers on site, can use an exemption in the portable fire extinguisher rule, but only with both written plans in place. A shop that has set up extinguishers for employee use, and is otherwise untouched by a triggering standard, may land somewhere else. Reading the plain text matters here.

Most small employers end up writing a plan anyway, because the reasons to have one go beyond the rule. An insurer or a customer may ask for it. New hires need to know where to go. Evacuation questions come up the first time an alarm sounds and nobody agrees on the assembly point.

This guide walks through the trigger, the minimum contents, the oral option at 10 or fewer employees, training and upkeep. By the end you should be able to decide whether you need a written plan and what it has to say.

How the trigger works under 1910.38

Start with 1910.38(a). It says an employer must have an emergency action plan whenever an OSHA standard in Part 1910 requires one. That is a cross-reference rule. You do not find your obligation in 1910.38 alone. You find it in whichever other standards apply to your operations, and those standards send you back to 1910.38 for the content.

Several Part 1910 standards reference the plan. The one most small employers meet first is the portable fire extinguisher standard, 1910.157. It ties to the plan through its exemptions in paragraph (b). Under (b)(1), an employer is exempt from the rest of 1910.157 if it has a written fire safety policy of immediate, total evacuation on the alarm, makes no extinguishers available in the workplace, and has an emergency action plan and a fire prevention plan that meet 1910.38 and 1910.39. That exemption does not apply if another Part 1910 standard requires an extinguisher. Under (b)(2), an employer whose emergency action plan names only certain employees to use the extinguishers, and has everyone else leave the area on the alarm, is exempt from the distribution rules in paragraph (d). An employer who provides extinguishers for employee use has other obligations under that standard, including training and inspection.

Other standards for specific hazards also reference the plan. We are not printing a full list from memory, because a wrong paragraph here would mislead you. The authoritative way to build the list is to search the current text of Part 1910 on eCFR for "1910.38" and read each hit in context. Your applicable standards depend on your chemicals, processes and equipment.

A practical way to do this is to list what you actually have on site. Think of flammable liquids, hazardous chemicals, any process that has its own emergency provisions, and your fire extinguisher decision. Then check whether each related standard reaches back to the plan. Our guide to which OSHA written programs are required covers the broader screening question across all the written programs.

The fire prevention side follows the same logic. The Fire Prevention Plan (29 CFR 1910.39) uses the same trigger and the same oral option. We cover it in OSHA fire prevention plan requirements, and many employers draft both plans together.

When the requirement does not apply, or applies narrowly

Three limits are worth knowing before you start writing.

First, if no Part 1910 standard that applies to you requires a plan, 1910.38 does not require one of its own accord. That does not make evacuation planning a bad idea. It only means the written-plan obligation under this standard is not triggered.

Second, jobsite construction work falls under 29 CFR 1926, not Part 1910. If your firm has a shop or yard side and a construction side, the shop may fall under 1910 while jobsites fall under 1926. SafetyWorkbook's MVP does not draft 1926 programs. A trades firm should treat the two sides separately.

Third, if you are a private employer in one of the 22 State Plan jurisdictions that cover the private sector, your state plan applies instead of federal OSHA. OSHA says a state plan must be at least as effective as the federal program, and it may add requirements. The list includes California, Michigan, Washington and Virginia, among others. This article covers the federal rule only, so check with your state agency for additions.

What the plan must contain

Once a plan is required, 1910.38(c) sets the minimum contents. Each element is something an employee should be able to act on without asking anyone.

  • Reporting. Procedures for reporting a fire or other emergency. Say who to tell and how: a phone number, an alarm pull station, a radio channel.
  • Evacuation procedures and exit route assignments. The types of evacuation and the routes people take. A floor sketch with exits marked is the quickest way to make this concrete.
  • Critical operations. Procedures for employees who must stay behind briefly to shut down or secure critical operations before they leave. If nobody stays, the plan can say so.
  • Accounting for employees. A way to confirm everyone is out after evacuation. This usually means a named assembly point and a named person with a headcount list.
  • Rescue and medical duties. Procedures for any employees who are assigned to perform them. If no employee has those duties, the plan says that too.
  • Contacts. The names or job titles of people or departments to contact for more information about the plan or for an explanation of duties under it.

Write each element in plain language and specific to your site. A plan that says "employees will evacuate to a safe location" has not told anyone where the location is. A plan that names the parking-lot corner by the north gate has.

Your site detail is where plans go stale. Exits get blocked by new racking. A department moves. The person named as headcount lead leaves. Because the plan describes your real floor, it drifts whenever the floor changes. Our written program checklist includes a step for comparing each plan against the current layout.

Warehouses and distribution sites have particular drift risks, such as moved racking, dock doors that get blocked and seasonal staffing. The notes in OSHA requirements for warehouses cover what else to watch there.

The oral option at 10 or fewer employees

Under 1910.38(b), the plan must be in writing, kept in the workplace and available for employee review. There is one exception. An employer with 10 or fewer employees may communicate the plan orally to employees. The same oral option appears in the Fire Prevention Plan rule at 1910.39.

Treat this option carefully. It changes how you communicate the plan, not whether the underlying elements exist. You still need to have decided each item above: how to report, where to exit, who counts heads. An oral plan means you explain those decisions out loud rather than handing over a document.

There are practical reasons many small employers write it down anyway:

  • A new hire can read it again after the first day.
  • A supervisor who was absent when you explained the plan can still find it.
  • An insurer or customer asking for a written plan gets one.
  • Your own memory of what you decided fades.

If you stay under the threshold today and grow, the written plan becomes the default. Headcount is one input. If a triggering standard applies, the question of which standard comes first. Confirm how OSHA counts employees for your situation with OSHA or your state plan agency.

Alarms, training and keeping the plan current

Writing the plan is the beginning. The rest of 1910.38 covers the parts that keep it working.

Alarm system. Paragraph (d) deals with the alarm system. It must be able to warn employees of an emergency in a way they can recognize, and the plan should say what the alarm means and what to do on hearing it. If you have a different signal for different events, say so.

Training. Paragraph (e) covers training. Employees who have been assigned specific duties under the plan, such as headcount or shutdown, need to be trained to carry them out. Everyone else needs to understand how to evacuate. SafetyWorkbook does not provide training content. What the app is built to help with is the record: who was trained, on which version of the plan, and when.

Reviewing the plan with employees. Paragraph (f) deals with reviewing the plan. You review it with each employee when the plan is first developed, when an employee is first assigned, when an employee's responsibilities under the plan change, and when the plan itself changes. That last trigger is the one that catches employers out. If you move an exit or change an assembly point, each affected employee needs the updated version, not the one in the binder from three years ago.

A training record that says "evacuation training, completed" is hard to use after a plan changes. A record that says "trained on the plan as adopted on a given date" tells you who still needs the update. Our guide to training records by program version goes into how to structure that.

Extinguishers. If your plan assumes employees will use portable extinguishers, the inspection duties under 1910.157 come with that decision. Our guide on fire extinguisher monthly inspection requirements walks through them.

A review rhythm that works

1910.38 does not set an annual review date, so the cadence is yours to choose. A reasonable approach for a small employer is to pick one fixed review date each year, then add event-based reviews when any of these happen:

  • a site is added or a layout changes
  • a new process, chemical or machine arrives
  • the person named in the plan leaves or changes roles
  • a drill or a real evacuation shows a gap

Write the owner's name next to the date. A review nobody owns tends not to happen.

How SafetyWorkbook is built to keep the plan current

SafetyWorkbook is a web workspace being built to draft and record written safety programs, including the Emergency Action Plan and the Fire Prevention Plan. It is not live yet. The waitlist is the entry point, and the pricing page describes the plans.

Here is what the app is built to do for this plan:

  • Applicability view. From your employer profile, it is built to mark the Emergency Action and Fire Prevention programs as applies, may apply or does not apply, with the reason and the federal standard. In a state-plan state it is built to show a notice that state rules may add to or differ from federal rules.
  • Drafting. The generator is deterministic and template-driven, with editable plain-language sections. It writes no AI-generated text. You edit the draft to match your floor.
  • Owner and review date. Each program is built to carry a named owner and a review date, with reminders 30 and 7 days before the date and again when it is overdue.
  • Change prompts. On the Professional plan and above, adding a site is built to flag the site-scoped programs and Emergency Action and Fire Prevention for review.
  • Revision history and adoption. Every edit is built to be logged. The review and adopt step is a visible step with a version date, and adopted versions are immutable. The adoption statement reads:

This program was drafted by SafetyWorkbook from information you provided. You own it and are responsible for it. SafetyWorkbook records your review and adoption; it does not certify that this program meets OSHA requirements and is not legal advice.

  • Training records per version. Records are tied to the exact version an employee was trained on. They can be entered by a user or collected through an account-free acknowledgement link that expires and can be revoked.
  • Exports. Each program can be exported as PDF or Word.

The limits are worth stating plainly. The app drafts and records. It does not decide whether your plan is adequate, does not run drills, does not supply training content and does not draft 1926 construction programs. It generates no state-plan content.

If you would rather start with a spreadsheet you own, the store sells the Emergency Action and Fire Prevention Plan Workbook, a downloadable Excel workbook. It also drafts and records. It does not certify anything.

When to get help, and where to go next

A written plan is a decision about your own site, so some questions are worth putting to someone qualified.

  • OSHA's On-Site Consultation Program offers no-cost, confidential safety and health services to small and medium-sized businesses. It is kept separate from enforcement, and OSHA says it conducts about 20,000 visits a year. If you want a person to look at your floor and your exits, start there. It does not maintain your programs, track versions or keep your training records. That is a difference in purpose, not a flaw.
  • A fire protection professional or your local fire authority can advise on alarm systems, exit routes and extinguisher placement for your building.
  • An attorney can answer a legal question about whether a particular standard applies to you. This article describes the text of the rule. It is not legal advice.
  • OSHA or your State Plan agency is the place to confirm the current text of any standard, how employees are counted, and any state-specific additions.

A sensible order of work looks like this:

  1. List the standards that apply to your operations and check each for a reference to 1910.38 on eCFR.
  2. Decide your extinguisher approach, since both exemptions in 1910.157(b) depend on having the plan.
  3. Draft the plan with the contents listed above, using your actual exits and assembly point.
  4. Name an owner and set a review date.
  5. Review the plan with each employee and record the version they were trained on.

If you want help keeping the plan current once it exists, join the SafetyWorkbook waitlist, or look at the workbook in the store for a file you can start with now. And if you want an outside view first, remember that OSHA's free On-Site Consultation Program is there for exactly that.

SafetyWorkbook is published by Rovaryn Digital Inc. It drafts and records written safety programs; it does not certify them, and this article is not legal advice. SafetyWorkbook is not affiliated with OSHA, the U.S. Department of Labor, the Bureau of Labor Statistics (BLS), any state-plan agency, ISNetworld, Avetta or Veriforce.